CVE: CVE-2026-35087, CVE-2026-35089, CVE-2026-35090
- CVSS 4.0: 9.3 (CERT-PL, CVE-2026-35087)
- CVSS 4.0: 8.7 (CERT-PL, CVE-2026-35089)
- CVSS 4.0: 9.3 (CERT-PL, CVE-2026-35090)
What happened
On 27 May 2026 CERT Polska published a description of three vulnerabilities in Slican phone systems. The numbering authority (CNA) is CERT-PL. The report was filed by Grupa ŻN.
CVE-2026-35087 is an authentication bypass in the administrative protocol (CWE-288). An attacker skips the login credentials by running a specific command. The text of that command is not given here. CERT-PL scores the entry CVSS 4.0 at 9.3, critical.
CVE-2026-35089 is a weak, predictable security key (CWE-1391). The key is derived from device properties that can be read without logging in, and it allows administrator data to be obtained. CERT-PL scores the entry CVSS 4.0 at 8.7, high.
CVE-2026-35090 is an authentication bypass through a call to the exchange modem from a specific number (CWE-288). That number is not given here. The call opens full access to the service protocol and the configuration panel, regardless of settings. If remote access is disabled, the call enables it for a time. CERT-PL scores the entry CVSS 4.0 at 9.3, critical.
In NVD these three records have status Deferred. There is no separate NVD score; the CERT-PL score remains. None of the identifiers is in the CISA KEV catalogue. As of the date of this note there is no report of known exploitation.
Who is affected
CVE-2026-35087 affects:
- IPx before version 6.61.0040,
- CCT-1668 and MAC-6400 before version 6.56.0430,
- CXS-0424 before version 6.30.0510,
- NCP before version 1.24.0250.
CVE-2026-35089 affects IPx, CCT-1668, MAC-6400, and CXS-0424 in the same ranges. NCP is not affected.
CVE-2026-35090 affects:
- IPL-256 and IPM-032 before version 6.61.0040,
- CCT-1668 and MAC-6400 before version 6.56.0430,
- CXS-0424 before version 6.30.0510.
The fixed versions are NCP 1.24.0250, IPx 6.61.0040, CCT-1668 6.56.0430, MAC-6400 6.56.0430, and CXS-0424 6.30.0510.
There will be no fix for withdrawn exchanges CCT-1668 (CCT1CPU), MAC-6400, and CXS-0424 on firmware 4.xx and older. Those lines were withdrawn in 2011–2012. New software first requires a hardware replacement. Slican recommends contacting its factory service.
What to do now
Raise the software to a fixed version. For exchanges on firmware 4.xx and older, which the manufacturer no longer patches, what remains is a hardware replacement and contact with Slican factory service.
The Slican hardening guide recommends: for remote access use the Slican keeper server instead of opening ports on the router, separate the exchange from the customer LAN, set firewall rules, and disable old TLS and SSL versions.
This is our recommendation, not advice from Slican or CERT Polska: limit network access to WebCTI and to the administrative interfaces. For CVE-2026-35090 it is worth checking whether the modem line is needed.
A review of access can start from the cybersecurity audit or from the security page.
How we can help
Updating the device stays with the administrator and the manufacturer. From us you can order, separately:
- SOC and 24/7 network monitoring
- cybersecurity audit
- vulnerability scanning
- networks and hardware (FortiGate, MikroTik, Teltonika)